• Fixed Type Draw-out Type Acb Air Circuit Breaker
  • Fixed Type Draw-out Type Acb Air Circuit Breaker
  • Fixed Type Draw-out Type Acb Air Circuit Breaker
  • Fixed Type Draw-out Type Acb Air Circuit Breaker
  • Fixed Type Draw-out Type Acb Air Circuit Breaker
  • Fixed Type Draw-out Type Acb Air Circuit Breaker

Fixed Type Draw-out Type Acb Air Circuit Breaker

Breaking Capacity: Low Voltage Circuit Breakers
Operation: Energy-storage Type
Speed: High-Speed Circuit Breaker
Arc-extinguishing Medium: Air
Installation: Fixed
Structure: Universal
Customization:
Diamond Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
SW45-2000
Certification
ISO9001-2000, CE, CB, CCC
Rated Curren
200A - 6300A
Rated Operational Voltage
415V 690V,
Number of Poles
3p 4p
Frequency of Operation (Number of Times/
20,10,10,
Transport Package
Export Carton
Specification
IEC60347-2
Trademark
Longroad/OEM
Origin
China
HS Code
8535210000
Production Capacity
1000 Pieces/Week

Product Description

1. Product Introduction:
With a rated current from 200A to 6300A, and rated operational voltage 415V 690V, 50Hz, the NA8G series air circuit breaker (hereinafter referred to as "breaker") is mainly used in the distribution network to distribute electric energy and protect lines and power equipment from being damaged by overload, under voltage, short circuit, single-phase grounding and other failures.
Having art-oriented appearance, high breaking capacity, zero arcover and vanities of intellectualized protection functions, that breaker can be used for selective protection with accurate action, no unnecessary power cut, and better power supply reliability.
The product allows the wire to enter or enter from the lower port, and the open frame (draw-out) circuit breaker has isolation function.
That breaker can be widely used for power stations, factories, mines and modern tall buildings, especially the distribution system in the intelligent building, and also widely used in green projects such as wind and solar power generation.
This product meets the requirements in IEC/EN 60947-2

2. Main technical parameters
Shell grade rated current Inm A 1600 3200 6300
Rated current In A   200,400,630,800,
1000,1250,1600
1600,2000,2500,
2900,3200
4000,5000 6300
Nominal insulation voltage Ui V 690 1000 1000  
Rated operational voltage Ue V 415 690 415 690 415  
Rated ultimate short circuit breaking capacity leu kA 50 25 100 65 120  
Rated service short circuit breaking capacity les kA 40 20 80 65 100  
Rated short time withstand current lcw,1s kA 40 20 80 65 100  
Number of poles   3P 4P 3P 4P 3P 4P 3P
Frequency of operation (number of times/h) 20 10 10  
  Mechanical life 3000 3000 2000  
Number of operations Electrical Life 1000 1000 500  
Flashover distance mm   0 0 0  
Line incoming pattern   Wire to enter from the upper or lower port Wire to enter from the upper or lower port Wire to enter from the upper or lower port  
  fixed type kg 22/26.5 52.5/66.5 -  
Net weight (3 poles/4 poles) draw-out type kg 42.5/55 98/121 210/233 233
Size(3 poles/4 poles) fixed type 320x(254/324)x258 406x(422/537)x329 -  
Height x width x depth draw-out type 351 x(282/352)x352 439x(435/550)x445 439x(835/928)x501 439x928x501
Fixed Type Draw-out Type Acb Air Circuit Breaker
Fixed Type Draw-out Type Acb Air Circuit Breaker

 