1p+N Residual Current Operated Circuit Breaker (Magnetic) a, AC Type Short-Circuit Current 6000A &1000A

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Still deciding? Get samples of US$ 5/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Plant Area
>2000 square meters
Management System Certification
ISO 9001, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001
  • 1p+N Residual Current Operated Circuit Breaker (Magnetic) a, AC Type Short-Circuit Current 6000A &1000A
  • 1p+N Residual Current Operated Circuit Breaker (Magnetic) a, AC Type Short-Circuit Current 6000A &1000A
  • 1p+N Residual Current Operated Circuit Breaker (Magnetic) a, AC Type Short-Circuit Current 6000A &1000A
  • 1p+N Residual Current Operated Circuit Breaker (Magnetic) a, AC Type Short-Circuit Current 6000A &1000A
  • 1p+N Residual Current Operated Circuit Breaker (Magnetic) a, AC Type Short-Circuit Current 6000A &1000A
  • 1p+N Residual Current Operated Circuit Breaker (Magnetic) a, AC Type Short-Circuit Current 6000A &1000A
Find Similar Products

Basic Info.

Model NO.
SRRE7-100
Arc-extinguishing Medium
Air
Installation
Fixed
Structure
Electromagnetic
Poles Number
1p+N, 3p+N
Type
RCCB
Function
RCCB, Residual Current Failure Protection
Certification
ISO9001-2000, CE, CB, CCC
-Rated Voltage Un
230 / 400VAC
Tripping  Category
Electromagnetic
Poles
1p+N, 3p+N
Rated Frequency
50/60Hz
Transport Package
Cartons
Trademark
LONGROAD/OEM
Origin
China
Production Capacity
100000PCS/Month

Packaging & Delivery

Package Size
21.60cm * 95.00cm * 90.00cm
Package Gross Weight
1.200kg

Product Description

1. General
1.1 Function
Control electric circuits.
Protect people against indirect contacts and additional protection against direct contacts.
Protect installations against fire hazard due to insulation faults.
Residual current circuit breakers are used in housing, tertiary sector and industry.
1.2 Selection
Detectable wave form
AC class :Tripping is ensured for slowly increasing sinusoidal AC residual currents.
A class :Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly
or increasing slowly.
Tripping sensitivity
10mA - precision instrument leakage protection and bathroom use.
30mA - additional protection against direct contact.
300mA - protection against indirect contacts, as well as fire hazard.
Tripping time
Instantaneous:It ensures instantaneous tripping (without time-delay).
2.Technical data
  Standard   IEC/EN 61008-1






Electrical features
Type (wave form of the earth leakage sensed)   AC, A
Rated current In A 16, 25, 32, 40, 63,80A
Poles   1P+N, 3P+N
Rated voltage Ue V 230/400~240/415,110/200~127/220
Rated sensitivity I△n A 0.01 (Only for 1P+N 16A, 25A),0.03,0.1, 0.3
Insulation voltage Ui V 500
Rated residual making and breaking capacity I△m A 500 (In=16A/25A/32A/40A)
630 (In=63A)
Short-circuit current Inc=Ic A 6000/10000
SCPD fuse A 10000
break time under I△n s ≤0.1
Rated frequency Hz 50/60
Rated impulse withstand voltage(1.2/50) Uimp V 6000
Dielectric test voltage at ind. Freq. for 1 min kV 2
Pollution degree   2


Mechanical features
Electrical life   2, 000
Mechanical life   2, 000
Fault current indicator   Yes
Protection degree   IP20
Ambient temperature (with daily average≤35ºC) ºC -5...+40
Storage temperation ºC -25...+70




Installation
Terminal connection type
Terminal size top/bottom for cable

Terminal size top/bottom for busbar

mm2
Cable/U-type busbar/Pin-type busbar
25
AWG
mm2
18-3
10
AWG 18-8
Tightening torque N·m 2.5
In-Ibs. 22
Mounting   On DIN rail EN 60715 (35mm) by means of fast clip device
Connection   From top and bottom
 
1p+N Residual Current Operated Circuit Breaker (Magnetic) a, AC Type Short-Circuit Current 6000A &1000A1p+N Residual Current Operated Circuit Breaker (Magnetic) a, AC Type Short-Circuit Current 6000A &1000A1p+N Residual Current Operated Circuit Breaker (Magnetic) a, AC Type Short-Circuit Current 6000A &1000A
1p+N Residual Current Operated Circuit Breaker (Magnetic) a, AC Type Short-Circuit Current 6000A &1000A

1p+N Residual Current Operated Circuit Breaker (Magnetic) a, AC Type Short-Circuit Current 6000A &1000A1p+N Residual Current Operated Circuit Breaker (Magnetic) a, AC Type Short-Circuit Current 6000A &1000A1p+N Residual Current Operated Circuit Breaker (Magnetic) a, AC Type Short-Circuit Current 6000A &1000A1p+N Residual Current Operated Circuit Breaker (Magnetic) a, AC Type Short-Circuit Current 6000A &1000Acompangy profile

        Longroad Electric Co.ltd founded in 2010,is located in the largest manufacturing base of low-voltage electric equipment of Liushi China.which is called"the Electric Device Metropolis of China"Longroad Electric specialized in the industrial electrical appliance,high-low voltage electrical equipment integrated with R&D,Manufacturing.International trade and service
       Longroad Electric Co,ltd regards quality of products as lifeLongroad Electric Coltd has been granted ISO9001 management system certifications.The comprehensive product line has more than 1000 models which have been approved by TUVCE,CQC. SGS.ROHS.SASO.the products sells well to UKSpain.PortuaalSingaporeTurkevRussiaKorea.South Africa.. more than 70 countries and regions
        Longroad Electric Co.ltd is always striving hard to provide the best services and competitve pricing to all customers.

Corporate Culture

       Enterprise policy:market oriented;technology driven; quality for survival;brand for developmentBusiness philosophy: provide value for customers: seek development for emplovees:take responsibilitv for societyTalent view the sea embraces all rivers and makes Jiaolong soar; the thousand boats compete to make the best of the worldQuality policy:people-oriented, pragmatic and
innovative: pursuina auality and servina the marketEnterprise spint:harmonymodesty.praamatism and developmentCustome
service: think for customers;be responsible for customers;make customers satisfiedEnterprise goal: to build an electrical manufacturing enterprise

service ldea

       "Intearity first.quality first"is the basic tenet of our companyOur quality policy is:installation specifications.timely maintenance. Abide by the contract.serve sincerelv and meet the needs of customers.We know that product auality is the basic and key factor of enterprise competitiveness, and service is the extension of product quality and one of the important factors of enterprise competition We are determined to treat our customers with"integrity":
1.All aspects of sincere service.That is.from the customer's electricity use report.enaineerina desian. euipment procurement installation and construction.eauipment commissionina and acceptancecompletion and power receivina to the test and detection during the future operation.We all provide all-round,whole process sincere service,try our best to meet the needs of customers.2,High quality returns.We strictly follow the provisions and requirements of the contract terms and engineering design on the equipment, and provide qualified products that meet the requirements,so as to complete the engineering construction and installation tasks within the specified time limit with the installation technology level
3,Active and stable aftercare service.We provide 24-hour emergency service after the project is powered on, that is, in case of abnormal operation of eauipment or accident power failure.as long as the customer calls us.we will rush to the site immediatelv remove the fault and resume power transmission

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now