• Plug-in Type 10ka High Breaking Capacity MCB
  • Plug-in Type 10ka High Breaking Capacity MCB
  • Plug-in Type 10ka High Breaking Capacity MCB

Plug-in Type 10ka High Breaking Capacity MCB

Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Speed: High-Speed Circuit Breaker
Arc-extinguishing Medium: Air
Installation: Fixed
Structure: MCB
Samples:
US$ 2/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
SRB8-63
Poles Number
1, 2, 3, 4
Type
Circuit Breaker
Function
Overload, Short-Circuit Protection
Certification
ISO9001-2000, CE, CB, CCC
Rated Current(a)
1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63
Rated Frequency
50/60Hz
Rated Voltage
230/400V AC
Rated Short-Circuit Making Capaity
10000A
Transport Package
120 Poles/Carton
Specification
IEC60898
Trademark
OEM/LONGROAD
Origin
China
Production Capacity
1000, 000 Poles/Month

Product Description

1.General
1.1 Function
protection of circuits against short-circuit currents, protection of circuits against overload currents, switch,isolation,
SRB8-63 circuit-breakers are used in domestic installation, as well as in commercial and industry electrical distribution systems.Selection

1.2Technical data of the network at the point considered: the earthing systems (TNS, TNC),
short-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device,
Network normal voltage. Tripping curves:
B curve (3-5In)
protection for people and big length cables in TN and IT systems.
C curve (5-10In)
protection for resistive and inductive loads with low inrush current.
D curve(10-14In)
protection for circuits which supply loads with high inrush current at the circuit closing
(LV/LV transformers, breakdown lamps).
Standard
    IEC/EN 60898-1
Rated current In A 1, 2, 3, 4, 6,10,16,20,25,32, 40, 50, 63
Poles   1P,2P,3P,4P
Rated voltage Ue V 230/400~240/415
Insulation voltage Ui V 500
Rated frequency   50/60Hz
Rated breaking capacity A 10000
Energy limiting class   3
Rated impulse withstand voltage(1.2/50) Uimp V 6000
Dielectric test voltage at ind. Freq. for 1 min kV 2
Pollution degree   2
Power loss per pole   Rated current (A) Max power loss per pole (W)
1, 2, 3, 4, 5, 6, 10 2
13, 16, 20, 25, 32 3.5
  40, 50, 63 5
Thermo-magnetic release characteristic   B, C, D
Electrical life   4, 000
Mechanical life   20, 000
Contact position indicator   Yes
Protection degree

ºC


ºC
IP20 30
-5...+40(Special application please refer to P14
for temperature compensation correction)
Reference temperature for setting
of thermal element
Ambient temperature (with
daily average≤35ºC)
Storage temperation ºC -25...+70
Terminal connection type   Cable/U-type busbar/Pin-type busbar

Terminal size top/bottom for cable
mm2 25
AWG 18-4

Terminal size top/bottom for busbar
mm2 10
AWG 18-8

Tightening torque
N·m 2.5
In-Ibs. 22
Mounting   On DIN rail EN 60715 (35mm) by means of fast clip device
Connection   From top and bottom
Auxiliary contact   Yes
Shunt release   Yes
Under voltage release   Yes
Alarm contant   Yes
Plug-in Type 10ka High Breaking Capacity MCBPlug-in Type 10ka High Breaking Capacity MCBPlug-in Type 10ka High Breaking Capacity MCBPlug-in Type 10ka High Breaking Capacity MCBPlug-in Type 10ka High Breaking Capacity MCB

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now