Lrpg RCBO 2p 4p Adjustable Current 5A 10A 15A 20A, 30A 40A 60A Electromagnetic Residual Current Circuit Breaker Overload Short-Circuit Protection Disjoncteur

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2016

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Plant Area
300 square meters
Management System Certification
ISO9001:2015
  • Lrpg RCBO 2p 4p Adjustable Current 5A 10A 15A 20A, 30A 40A 60A Electromagnetic Residual Current Circuit Breaker Overload Short-Circuit Protection Disjoncteur
  • Lrpg RCBO 2p 4p Adjustable Current 5A 10A 15A 20A, 30A 40A 60A Electromagnetic Residual Current Circuit Breaker Overload Short-Circuit Protection Disjoncteur
  • Lrpg RCBO 2p 4p Adjustable Current 5A 10A 15A 20A, 30A 40A 60A Electromagnetic Residual Current Circuit Breaker Overload Short-Circuit Protection Disjoncteur
  • Lrpg RCBO 2p 4p Adjustable Current 5A 10A 15A 20A, 30A 40A 60A Electromagnetic Residual Current Circuit Breaker Overload Short-Circuit Protection Disjoncteur
  • Lrpg RCBO 2p 4p Adjustable Current 5A 10A 15A 20A, 30A 40A 60A Electromagnetic Residual Current Circuit Breaker Overload Short-Circuit Protection Disjoncteur
  • Lrpg RCBO 2p 4p Adjustable Current 5A 10A 15A 20A, 30A 40A 60A Electromagnetic Residual Current Circuit Breaker Overload Short-Circuit Protection Disjoncteur
Find Similar Products

Basic Info.

Model NO.
LRPG-4P
Speed
Normal Type Circuit Breaker
Arc-extinguishing Medium
Air
Installation
Fixed
Structure
Electromagnetic
Poles Number
1p+N, 3p+N
Type
RCBO
Function
Conventional Circuit Breaker, Overcurrent Protection, RCCB, Residual Current Circuit Breaker
Certification
ISO9001-2000, CE, CCC
Model
Lrpg-4p
Rated Voltage(V)
AC400V
Sensitivity
300mA, 500mA
Number of Poles
3p+N
Transport Package
Export Carton
Specification
IEC60947-2 NFC61450
Trademark
Longroad/OEM
Origin
China
HS Code
8536200000
Production Capacity
100, 000PCS/Month

Packaging & Delivery

Package Size
42.50cm * 23.00cm * 33.50cm
Package Gross Weight
24.000kg

Product Description

1 Scope of application
LRPG Series circuit breaker with residual current protection is a high-performance adjustable circuit breaker with triple protection functions of leakage, overload and short circuit.  lt is applicable to AC 50/60Hz and rated voltage 230/240V. Places with rated current of 60A and below. lt is mainly used for electric leakage, overload and short circuit protection of lighting, energy meter boxes, distribution lines and equipment of residential buildings, office buildings and similar buildings, and can also be used for infrequent operation and switching of lines under normal conditions.

2)The product standard
IEC/EN 60947-2, 
NFC 61450



3 Product features
Compact structure, multiple rated current ranges can be selected,which can solve the problem of frequent replacement of circuit breakers due to increasing load.

4. Main technical parameter
4.1

 

Type LRPG
Poles 3P+N
Rated Current(A) 10~30A(10,15,20,25,30)A
30~60A(30,40,50,60)A
Rated Voltage(V) 230V/400V
Leakage operating current(mA) 300/500mA
leakage non -operating current(mA) 150mA/250mA
Short-circuit Breaking Capacity Icn (A) 4500A
Rated frequency:(Hz) 50/60Hz
Electrical Life(times) 1500
Mechanical Life(times) 8500

Note: breaking capacity 6000A: rated operation breaking capacity lcs=rated limit breaking Capacity lcu=6000A
4.2
 

Reference temperature Current multiple Current name Action time

+40ºC
non tripping current 1.05Ir 1h
  tripping current 1.3Ir <1h


Note: breaking capacity 6000A: rated operation breaking capacity lcs=rated limit breaking Capacity lcu=6000A
4.3

Residual current (mA) 300,500
Remaining protection electric life(times) 3000
Setting value of short-circuit protection 10In
Type of residual current release ELM
Using type A
Rated impulse withstand voltage(KV) 6
Residual current protection type AC

Note: ELM is the electromagnetic tripping type product used for the residual current release of the product; Type A Residual current

protection
 is used to protect for sinusoidal AC residual currents and DC residual currents

Type AC Residual current protection is used to protect for sinusoidal AC residual currents.

4.3
Reference temperature Current multiple Current name Action time

+40ºC
non tripping current 1.05Ir 1h
tripping current 1.3Ir <1h




5.operating principles

5.1 Service connections are the interface between the Utility and the end- user customer.
5.2 They connect the customer's electrical installation to the power distribution  network.

6. Advantages

6.1 Low-cost product,suitable for conventional service connections.

6.2 Multiple  rating  device.
6.3 Several levels of earth leakage sensitivity.
6.4 Complies with the French NFC 61450 standard.
7. Convenience and safety
7.1Prevention of over-voltage

The neutral pole is designed to close first and open last to  maintain a fixed potential.

7.2 Protection against nuisance tripping

Immunized against voltage surges of atmospheric origin
Uninterrupted power supply for greater user convenience


7.3 Safety checking

·The test button may be used to simulate an earth leakage fault,  thereby providing a simple way  to check the system.

7.4 Easy operation

Operation in all positions

ON/OFF control by push-button

Rating easily changed

lead-saleable terminal shields

captive terminal screws

pivoting terminals

copper cables up to 35 mm²

neutral identified in blue

8.Series model specification and its meaning
LRPG-2P/  LRPG: company model2P:1P+N, rated current

9 Normal installation and working conditions
a) Working environment of LRPG products is -5°C~40 'C, humidity≤ 95%;

b) The altitude of the installation site shall not exceed 2000m; Note: lf the altitude of the installation site exceeds 2000m, the use of the circuit breaker shall be negotiated with the manufacturer.
c)Special measures shall be taken for occasional condensation due to temperature change;

d)Installation position: no obvious shaking, impact vibration, explosive corrosive gas, rain and snow;
e) Installation conditions: the external magnetic field of the installation
 site shall not exceed 5 times of the geomagnetic field in any direction;
f) Installation category: ll or ll;
g) Pollution level: 3;
h)Transportation and storage conditions: the product storage and transportation environment shall be dry and ventilated, free from significant impact and vibration, direct sunlight, rain, dust, chemical gas corrosion,etc

10.Boundary and installation dimensions (unit: mm)
Lrpg RCBO 2p 4p Adjustable Current 5A 10A 15A 20A, 30A 40A 60A Electromagnetic Residual Current Circuit Breaker Overload Short-Circuit Protection DisjoncteurLrpg RCBO 2p 4p Adjustable Current 5A 10A 15A 20A, 30A 40A 60A Electromagnetic Residual Current Circuit Breaker Overload Short-Circuit Protection Disjoncteur






M4 screws are recommended to be used as the mounting screws, andthe mounting dimensions are shown in the dimension drawing above.
Table of sectional area of product wire connection

Rated Current In/A In<6A 6A<In13A 13A<In20A 20A<In25A 25A<In32A 32A<In50A 50A<In63A
Sectional area of conductor mm² 1 1.5 2.5 4 6 10 16

8.Instructions for changing rated current gear
a. The default setting of the circuit breaker at the factory is the maximum current gear;
b. When replacing the rated current gear, please ensure that the circuit breaker is disconnected;
c. By observing the corresponding current indicating window, remove the gear screw at the inlet end with a slotted screwdriver (Fig. Fig.1);
d. Remove the protective cover of the incoming line end (Fig. 2);
e. Remove the middle cover, select the required current gear, and adjust the current gear (Figure 3);
f. Then install the middle cover and protective cover, and screw the gear screw to the corresponding position to ensure that the screw is tightened, otherwise the product will jump early

 

 

Lrpg RCBO 2p 4p Adjustable Current 5A 10A 15A 20A, 30A 40A 60A Electromagnetic Residual Current Circuit Breaker Overload Short-Circuit Protection DisjoncteurLrpg RCBO 2p 4p Adjustable Current 5A 10A 15A 20A, 30A 40A 60A Electromagnetic Residual Current Circuit Breaker Overload Short-Circuit Protection DisjoncteurLrpg RCBO 2p 4p Adjustable Current 5A 10A 15A 20A, 30A 40A 60A Electromagnetic Residual Current Circuit Breaker Overload Short-Circuit Protection DisjoncteurLrpg RCBO 2p 4p Adjustable Current 5A 10A 15A 20A, 30A 40A 60A Electromagnetic Residual Current Circuit Breaker Overload Short-Circuit Protection DisjoncteurLrpg RCBO 2p 4p Adjustable Current 5A 10A 15A 20A, 30A 40A 60A Electromagnetic Residual Current Circuit Breaker Overload Short-Circuit Protection DisjoncteurLrpg RCBO 2p 4p Adjustable Current 5A 10A 15A 20A, 30A 40A 60A Electromagnetic Residual Current Circuit Breaker Overload Short-Circuit Protection DisjoncteurLrpg RCBO 2p 4p Adjustable Current 5A 10A 15A 20A, 30A 40A 60A Electromagnetic Residual Current Circuit Breaker Overload Short-Circuit Protection Disjoncteur


 