• Cost-Effective High-Speed with Low Voltage Mould Mccb
  • Cost-Effective High-Speed with Low Voltage Mould Mccb
  • Cost-Effective High-Speed with Low Voltage Mould Mccb
  • Cost-Effective High-Speed with Low Voltage Mould Mccb
  • Cost-Effective High-Speed with Low Voltage Mould Mccb
  • Cost-Effective High-Speed with Low Voltage Mould Mccb

Cost-Effective High-Speed with Low Voltage Mould Mccb

Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Speed: High-Speed Circuit Breaker
Arc-extinguishing Medium: Air
Installation: Fixed
Structure: MCCB
Samples:
US$ 10/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
LRM1
Poles Number
3, 4
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Overcurrent Protection
Certification
ISO9001-2000, CE, CB
Model
Lrm1
Number of Poles
3p, 4p
Current Value
63A~1600A
Rated Operating Voltage(V)
400V
Transport Package
Carton
Specification
IEC60947-2
Trademark
Long Road/OEM
Origin
China
Production Capacity
100, 000 Pieces/Month

Product Description

1. Application
LRM1 series moulded case circuit breaker is one of products developed and manufactured by adopting international advanced technology. It is supplied with rated insulating voltage 550 and 800V and used for circuit of AC 50/60Hz, rated operating voltage AC 400V (or below), rated operating current up to 1600A for infrequent changing over and starting of the motors.The products conforms to IEC60947-2 standard.
2. Main Technical Specification(table1)

Type

Rated
current (A)

Polenum-ber

Ratedinsui-atingvolt-age(V)

Rated
operat-ingvolt-age(V)

Arcing-
over
distance
(mm)

Ultimate
short
circuit
breaking
capacity
(KA)

Servies
short
circuit
breaking
capacity
(KA)

Operation
perform-
ance

Utiliza-tioncat-egory

Load

Unload

LR1-63L

(6),10
16,20
25 ,32
40,50
63

3, 4

500V

400V

0

25

18

1500

8500

A

LRM1-63M

0

50

35

LRM1-100L

(10),16
20,25
32,40
50,63
80,100

800V

0(≤50)

35

22

LRM1-100M

0(≤50)

50

35

LRM1-100H

0(≤50)

85

50

1000

7000

LRM1-225L

100,125
160,180
200,225

≤50

35

22

LRM1-225M

≤50

50

35

LRM1-225H

≤50

85

50

1000

4000

LRM1-400L

225,250
315,350
400

≤50

50

35

LRM1-400M

≤100

65

42

LRM1-630L

400,500
630

≤100

50

35

LRM1-630M

≤100

65

42

LRM1-630H

≤100

100

65

LRM1-800M

630,700
800

3

≤100

75

50

LRM1-800H

≤100

100

65

LRM1-1250M

1000,1250

≤100

100

65

LRM1-1250H

≤100

125

75

LRM1-1600M

1600

≤100

150

80

Note: 6A without thermal protection 
The N-pole of four-poles breaker is sited at the right side of the product has four types: 
Type A: Without current trip-lease on N pole which making all the time, not closing and opening with the other three poles. 
Type B: Without current trip-release on N pole which closing and opening with the other poles. 
Type C: With current trip-release which closing and opening with the other three poles.
Type D: With current trip-release which making all the time not closing and opening with the other three poles. 
3. Protection Characteristic
The thermodynamic release of a circuit breaker provides the feature of inverse time-delay, while the magnetic release is the instantaneous operation as shown on table 2(distribution circuit breaker) and table 3 (motor protection circuit breaker). 
Table2

Rated current of release (A)

Thermodynamic release( ambient temperature ) land +40°C marine +45°C

Operating current of magnetic release (A)

1.05In(cold state) Inoperative time(h)

1.30In(heat state) Operative time(h)

10≤In≤63

≥ 1

< 1

10In±20%

63

 

 

 

 

 

 

Cost-Effective High-Speed with Low Voltage Mould Mccb
Cost-Effective High-Speed with Low Voltage Mould Mccb

 

Cost-Effective High-Speed with Low Voltage Mould Mccb



Cost-Effective High-Speed with Low Voltage Mould Mccb









 

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now