• Model Lrr6 3p Smart Circuit Breaker Made in China
  • Model Lrr6 3p Smart Circuit Breaker Made in China
  • Model Lrr6 3p Smart Circuit Breaker Made in China
  • Model Lrr6 3p Smart Circuit Breaker Made in China
  • Model Lrr6 3p Smart Circuit Breaker Made in China
  • Model Lrr6 3p Smart Circuit Breaker Made in China

Model Lrr6 3p Smart Circuit Breaker Made in China

Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Air
Installation: Fixed
Structure: MCB
Samples:
US$ 17.12/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
LRR6-3P-RS485
Poles Number
1,2,3,4
Type
Circuit Breaker
Function
Overcurrent Protection
Standard
IEC/En60898-1Tiec/En60947-2
Protection
Overcurrent and Short Circuit
Type of Trip
Thermo-Magnetic
No.of Poles
1p,2p,3p,4p
Rated Currents in
1,2,3,4,5,6,10,16,20,25,32,40,50,63A
Rated Voltage Ue
240/415V~
Rated Frequency
50/60Hz
Rated Breaking Capacity
6,000A
Transport Package
120 PCS/Carton Bag
Specification
91× 18× 61mm
Trademark
longroad
Origin
China
Production Capacity
250000 Poles/Month

Product Description

1.Model LRR6 series Smart Auto Recloser Application                   
1.1 LRR6 series smart auto recloser is designed to automatically reclose after the relevant protection device trips when a temporary fault occurs in the power system, so as to improve the reliability of the circuit power supply
1.2 It can be widely used in power grid terminal lines, unattended mobile phone base stations, elevators, air conditioners, smart phones, smart homes, smart factories, new energy vehicle charging piles, etc.
2.Model LRR6 series Smart Auto Recloser Characteristics
2.1 It can be matched with MCB or RCD. When the MCB or RCD trips unexpectedly, it does not need to be closed manually, reducing manual maintenance costs, and timely troubleshooting to improve efficiency.
2.2 It can realize remote opening and closing control, timing tasks, and obtain the current switch status through wifi or a platform with RS485 connection.
2.3 Built-in multiple reclosing times, continuous closing failure within a certain period of time can send an alarm signal through the LED indicator light or APP. (for specific time and frequency, please refer to the parameter table)

2.4 Reclosing times and delay time can be set up and adjusted as per request.  
2.5 With manual/automatic selection switch and mechanical lock function.  
2.6 Used in conjunction with circuit breakers and leakage switches to provide overload, short circuit and leakage protection.  
2.7 The working status is indicated by LED etc.
3.Model LRR6 series Smart Auto Recloser Main technical parameters
Model LRR6-Wifi LRR6-RS485
Communication method Wifi, ZigBee RS485
Supply terminals L-N
Rated voltage Ue AC 230V
Power consumption AC max.1VA (standby), max.20VA (action)
Supply voltage tolerance ±10%
Status Indicator Green LED Red, green and yellow tri-color LED
Trip time  1s
Mechanical life 10000 Cycles
Electrical life 4000 Cycles
Ambient temperature -20ºC to +55ºC (-4 ºF to 131 ºF )
Storage temperature -35ºC to +75ºC (-22 ºF to 158 ºF )
Installation Mounting on 35mm DIN rail
Pollution degree IP20
Supply terminal size for cable Max. 2.5mm²
Dimensions 91×18×61mm
Compatible Device MCB (LRM6-63), RCCB, RCBO (LRE6-63, LRE6L-63)
(More compatible devices are in development)

Remark:The Wifi-type smart module needs to configure the network when it is used for the first time, and the Tuya App needs to be downloaded and installed on the mobile phone. The smart module and the mobile phone are required to be matched under the same wireless network. If the network device is replaced, the smart module needs to reconfigure the network.
4.Description of Automatic, Manual Mode Switches and Mechanical Locksof Smart Auto Recloser 
AUTO  Mode: Allow remote control (Tuya APP, RS485).
MANU Mode: Remote operation is prohibited
Mechanical Padlock:When the mechanical lock is pulled out, the device will enter the locked state, and the device will not be closed to ensure the safety of on-site maintenance. Press the mechanical lock to restore it.
4.Model LRR6 Smart MCB Technical Parameter
Standard IEC/EN60898-1 IEC/EN60947-2
Protection Overcurrent and short circuit
Type of trip Thermo-magnetic
No.of poles 1P,2P,3P,4P
Rated currents In 1,2,3,4,5,6,10,16,20,25,32,40,50,63A
Rated voltage  Ue 240/415V~
Rated frequency 50/60Hz
Rated breaking capacity 6,000A
Energy Limiting Class 3
Rated impulse withstandard voltage(1.5/50) Uimp 6,000V
Dielectric test voltage at Ind. Freq.for 1 min 2kV
Thermal release characteristic (1.13-1.45) x In (1.05-1.30) x In
Magnetic release characteristic B: (3-5) x In, C: (5-10) x In (8-12) x In
Electrical life 8,000 Cycles
Mechanical life 20,000 Cycles
Contact position indicator Yes
Protection degree IP20
Ambient temperature -5ºC to +40ºC Max.95%humidity
Terminal connection type Cable/Pin-type busbar
Max.terminal size for cable 25mm2
Max.tightening torque 2.5N.m
Installation Mounting on 35mm DIN rail
Connection From top and bottom
5.LRR6 Smart Closer with LRM6-63 MCB Product Size and Wiring Method
Model Lrr6 3p Smart Circuit Breaker Made in China



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now